Review





Similar Products

86
Haemoscope Corporation teg 5000 device
Teg 5000 Device, supplied by Haemoscope Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/teg+5000+devices/pmc12515607-130-6-8?v=Haemoscope+Corporation
Average 86 stars, based on 1 article reviews
teg 5000 device - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

90
Haemonetics thromoelastography (teg) device teg 5000
Thromoelastography (Teg) Device Teg 5000, supplied by Haemonetics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/teg+5000+devices/us12337260-2830-6-14?v=Haemonetics
Average 90 stars, based on 1 article reviews
thromoelastography (teg) device teg 5000 - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Haemonetics teg 5000 device
Teg 5000 Device, supplied by Haemonetics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/teg+5000+devices/pm40016048-21-115-118?v=Haemonetics
Average 90 stars, based on 1 article reviews
teg 5000 device - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

86
Rotem Industries teg 5000 devices
Teg 5000 Devices, supplied by Rotem Industries, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/teg+5000+devices/pm39794229-64-23-20?v=Rotem+Industries
Average 86 stars, based on 1 article reviews
teg 5000 devices - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

90
Haemoscope Corporation teg device kaolin thromboelastography teg 5000 system
Teg Device Kaolin Thromboelastography Teg 5000 System, supplied by Haemoscope Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/teg+5000+devices/pmc10657755-97-6-15?v=Haemoscope+Corporation
Average 90 stars, based on 1 article reviews
teg device kaolin thromboelastography teg 5000 system - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Haemonetics teg device teg 5000
Teg Device Teg 5000, supplied by Haemonetics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/teg+5000+devices/pm36951240-93-1-5?v=Haemonetics
Average 90 stars, based on 1 article reviews
teg device teg 5000 - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Rotem Industries cup-and-pin legacy devices teg 5000
Cup And Pin Legacy Devices Teg 5000, supplied by Rotem Industries, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/teg+5000+devices/pmc10009294-217-4-10?v=Rotem+Industries
Average 90 stars, based on 1 article reviews
cup-and-pin legacy devices teg 5000 - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Haemonetics teg® 5000 device
Linear regression plots (A–D) for all thromboelastography <t>(TEG)</t> parameters comparing <t>TEG®5000</t> vs. TEG®6S from n = 100 patients yielding 225 comparisons analyzed from samples collected from rewarming and intensive care unit (ICU) time points. The solid line represents the best-fit linear regression line and the dotted lines represent 95% confidence interval of the best-fit line. Regression formula and Pearson r values for the best-fit of the slope are represented.
Teg® 5000 Device, supplied by Haemonetics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/teg+5000+devices/pmc09639686-53-19-22?v=Haemonetics
Average 90 stars, based on 1 article reviews
teg® 5000 device - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

Image Search Results


Linear regression plots (A–D) for all thromboelastography (TEG) parameters comparing TEG®5000 vs. TEG®6S from n = 100 patients yielding 225 comparisons analyzed from samples collected from rewarming and intensive care unit (ICU) time points. The solid line represents the best-fit linear regression line and the dotted lines represent 95% confidence interval of the best-fit line. Regression formula and Pearson r values for the best-fit of the slope are represented.

Journal: The Journal of ExtraCorporeal Technology

Article Title: Comparison of Thromboelastography Devices TEG ® 6S Point of Care Device vs. TEG ® 5000 in Pediatric Patients Undergoing Cardiac Surgery

doi: 10.1182/ject-42-49

Figure Lengend Snippet: Linear regression plots (A–D) for all thromboelastography (TEG) parameters comparing TEG®5000 vs. TEG®6S from n = 100 patients yielding 225 comparisons analyzed from samples collected from rewarming and intensive care unit (ICU) time points. The solid line represents the best-fit linear regression line and the dotted lines represent 95% confidence interval of the best-fit line. Regression formula and Pearson r values for the best-fit of the slope are represented.

Article Snippet: In a recently published article, we have shown an association of low rewarming TEG maximum amplitude (MA) measured on TEG ® 5000 (Haemonetics Inc., Braintree, MA) device with increased risk for bleeding in pediatric patients undergoing high-risk cardiac surgery ( 5 ).

Techniques:

Bland–Altman plots (A–D) for all thromboelastography (TEG) parameters (R-time, K-time, angle, maximum amplitude [MA]) (n = 225). Average of the TEG parameters from both methods (TEG®5000 and TEG®6S) on X-axis was plotted against difference between the TEG parameters from both methods (TEG®5000 − TEG®6S) on the Y-axis. The solid line represents 95% limits of agreement and the dashed line represents the bias.

Journal: The Journal of ExtraCorporeal Technology

Article Title: Comparison of Thromboelastography Devices TEG ® 6S Point of Care Device vs. TEG ® 5000 in Pediatric Patients Undergoing Cardiac Surgery

doi: 10.1182/ject-42-49

Figure Lengend Snippet: Bland–Altman plots (A–D) for all thromboelastography (TEG) parameters (R-time, K-time, angle, maximum amplitude [MA]) (n = 225). Average of the TEG parameters from both methods (TEG®5000 and TEG®6S) on X-axis was plotted against difference between the TEG parameters from both methods (TEG®5000 − TEG®6S) on the Y-axis. The solid line represents 95% limits of agreement and the dashed line represents the bias.

Article Snippet: In a recently published article, we have shown an association of low rewarming TEG maximum amplitude (MA) measured on TEG ® 5000 (Haemonetics Inc., Braintree, MA) device with increased risk for bleeding in pediatric patients undergoing high-risk cardiac surgery ( 5 ).

Techniques:

Bland–Altman parameters for agreement of limits:  TEG  ® 5000 vs.  TEG  ® 6S (n = 225) and  TEG  ® 6S-FLEV vs. Clauss-fibrinogen (n = 54).

Journal: The Journal of ExtraCorporeal Technology

Article Title: Comparison of Thromboelastography Devices TEG ® 6S Point of Care Device vs. TEG ® 5000 in Pediatric Patients Undergoing Cardiac Surgery

doi: 10.1182/ject-42-49

Figure Lengend Snippet: Bland–Altman parameters for agreement of limits: TEG ® 5000 vs. TEG ® 6S (n = 225) and TEG ® 6S-FLEV vs. Clauss-fibrinogen (n = 54).

Article Snippet: In a recently published article, we have shown an association of low rewarming TEG maximum amplitude (MA) measured on TEG ® 5000 (Haemonetics Inc., Braintree, MA) device with increased risk for bleeding in pediatric patients undergoing high-risk cardiac surgery ( 5 ).

Techniques:

Linear regression analysis and Bland–Altman plots comparing TEG®6S-FLEV and Clauss-fibrinogen (mg/dl) method (n = 54). (A) For linear regression analysis plots, solid line represents the best-fit linear regression line and the dotted lines represent 95% confidence interval of the best-fit line. Regression formula and Pearson r values for the best-fit of the slope are represented. (B) For Bland–Altman plots, average of the TEG parameters from both methods (TEG®5000 and TEG®6S) on X-axis was plotted against difference between the TEG parameters from both methods (TEG®5000 − TEG®6S) on the Y-axis.

Journal: The Journal of ExtraCorporeal Technology

Article Title: Comparison of Thromboelastography Devices TEG ® 6S Point of Care Device vs. TEG ® 5000 in Pediatric Patients Undergoing Cardiac Surgery

doi: 10.1182/ject-42-49

Figure Lengend Snippet: Linear regression analysis and Bland–Altman plots comparing TEG®6S-FLEV and Clauss-fibrinogen (mg/dl) method (n = 54). (A) For linear regression analysis plots, solid line represents the best-fit linear regression line and the dotted lines represent 95% confidence interval of the best-fit line. Regression formula and Pearson r values for the best-fit of the slope are represented. (B) For Bland–Altman plots, average of the TEG parameters from both methods (TEG®5000 and TEG®6S) on X-axis was plotted against difference between the TEG parameters from both methods (TEG®5000 − TEG®6S) on the Y-axis.

Article Snippet: In a recently published article, we have shown an association of low rewarming TEG maximum amplitude (MA) measured on TEG ® 5000 (Haemonetics Inc., Braintree, MA) device with increased risk for bleeding in pediatric patients undergoing high-risk cardiac surgery ( 5 ).

Techniques: